[{"_geo": {"lat": 50.128063, "lng": 8.6013212}, "amenities": ["Client Implementation Services", "Installation Services", "24/7 Remote Hands Services", "Facility Services", "Additional Security Services"], "certifications": ["EN 50600 (Building E, F/G, H)", "ISO 9001", "ISO 50001", "ISO 27001 IT-GS (BSI)", "ISAE 3402 Type II", "PCI DSS"], "facility": {"address": "Eschborner Landstra\u00dfe 100", "city": "Frankfurt am Main", "connectivity": {"hasHyperscale": false, "hasInterconnect": true, "hasRetail": false, "hasWholesale": false, "networkProviders": ["Carrier- and cloud-neutral", "Carrier-Meet-Me-Rooms", "Carrier-Access-Rooms", "Carrier-mix", "Connectivity and dark fiber infrastructure", "Redundant cabling infrastructure", "Pre-Cabling", "High-performance internet access", "Inter data center connectivity between NTT facilities", "Multi Service Interconnection Platform"]}, "country": "Germany", "name": "Frankfurt 1", "overview": "NTT Frankfurt 1 is Germany\u2019s largest individual data center site, offering around 50,000m\u00b2 of data center and technical space. The facility provides high-performance, carrier-neutral connectivity with extensive redundancy, security, and sustainability measures.", "state": "NULL", "stateAbbr": "NULL", "url": "/ntt-frankfurt-1", "worldRegion": "europe", "yearBuilt": "NULL", "zipcode": "60489"}, "hasSecurity": true, "id": 784, "media": ["NULL"], "powerAndCooling": {"cooling": {"configuration": "High-efficiency chiller systems with free cooling, CRAH units, redundant cooling and cold water loops, heat recovery with heating pumps", "redundancy": "NULL"}, "density": "8 \u2013 12MW per data center building", "standbyPower": {"configuration": "Redundantly designed emergency power system with diesel generators for each building", "redundancy": "N+1"}, "ups": {"configuration": "Separate, dual UPS systems (A- and B-supply) with 2N redundancy", "redundancy": "2N"}, "utilityFeeders": "Power supply at 110kV level with on-site substation and three 110/20kV transformers (N+1)"}, "provider": "NTT Global Networks", "providerId": 31, "providerLogo": "https://colo.nyc3.cdn.digitaloceanspaces.com/logos/ntt-global-data-centers.png", "specifications": {"building": {"colocationSpace": 515590, "type": "NULL"}, "fireProtection": {"detection": "VESDA (Very Early Smoke Detection Alarm System), automatic digital fire alarm system", "suppression": "Firefighting system based on an argon or nitrogen extinguishing gas system"}, "floodAndSeismic": {"floodZone": "NULL", "seismicRating": "NULL"}}, "uptime": "99.999% power uptime availability"}]
{"_geo": {"lat": 50.121432, "lng": 8.7386105}, "amenities": ["Client implementation", "Installation services", "24/7 Remote Hands services", "Facility services"], "certifications": ["ISO 9001", "ISO 50001", "ISO 27001 IT-GS (BSI)", "PCI DSS"], "facility": {"address": "Hanauer Landstra\u00dfe 320", "city": "Frankfurt am Main", "connectivity": {"hasHyperscale": false, "hasInterconnect": true, "hasRetail": false, "hasWholesale": false, "networkProviders": ["Carrier- and cloud-neutral", "Carrier-mix", "Connectivity and dark fiber infrastructure", "Redundant cabling infrastructure", "High-performance internet access", "Inter data center connectivity between NTT facilities", "Multi Service Interconnection Platform"]}, "country": "Germany", "name": "Frankfurt 2", "overview": "Frankfurt 2 Data Center is one of NTT\u2019s smaller sites in Germany, located in a connectivity-rich area in the East of Frankfurt. It is a DE-CIX enabled site, offering carrier- and cloud-neutral connectivity, high-performance infrastructure, and secure colocation solutions.", "state": "NULL", "stateAbbr": "NULL", "url": "/ntt-frankfurt-2", "worldRegion": "europe", "yearBuilt": "NULL", "zipcode": "60314"}, "hasSecurity": true, "id": 1055, "media": ["NULL"], "powerAndCooling": {"cooling": {"configuration": "Redundant water-cooled system supported by free-cooling (N+1), star-shaped chilled water pipes to CRAH units with redundant pumps", "redundancy": "N+1"}, "density": "1.1MW IT load", "standbyPower": {"configuration": "Emergency generators (2 x 1,400kVA) with 48-hour fuel storage", "redundancy": "NULL"}, "ups": {"configuration": "N+1 redundant bridging time minimum 15 minutes battery at full load", "redundancy": "N+1"}, "utilityFeeders": "Own medium-voltage feed from the European grid via local power supplier (3 x 1,000kVA transformer station)"}, "provider": "NTT Global Networks", "providerId": 31, "providerLogo": "https://colo.nyc3.cdn.digitaloceanspaces.com/logos/ntt-global-data-centers.png", "specifications": {"building": {"colocationSpace": 16145, "type": "NULL"}, "fireProtection": {"detection": "Very Early Smoke Detection Alarm Systems (VESDA), automatic digital fire alarm system", "suppression": "Mobile gas extinguishing systems and hand-held fire extinguishers"}, "floodAndSeismic": {"floodZone": "NULL", "seismicRating": "NULL"}}, "uptime": "99.95% power uptime availability"}